This manual provides essential guidance for the safe and effective use of the Invacare Oxygen Concentrator, ensuring optimal performance and patient care through detailed instructions and safety precautions.

What is the Invacare Concentrator?

The Invacare Concentrator is a medical device designed to provide supplemental oxygen by separating oxygen from room air using molecular sieve technology. It is intended for patients with respiratory conditions requiring additional oxygen support. Available in models like IRC5LXAW and IRC5LXO2AW, it offers compatibility with the HomeFill system for filling oxygen cylinders. The device delivers oxygen through a nasal cannula, with concentration levels between 87% and 95.6%. It is not intended for life support but serves as a reliable source of supplemental oxygen therapy.

Installation and Setup Guide

This guide outlines the steps for properly installing and setting up the Invacare concentrator, ensuring safe and effective operation in a home environment.

Pre-Installation Checks

Before installing the Invacare concentrator, ensure the area is well-ventilated and meets power supply requirements. Verify all components and connections are secure. Check for leaks in tubing and ensure the molecular sieve is intact. Confirm the oxygen concentration levels are within the specified range of 87 to 95.6%. Refer to the user manual for specific guidelines and ensure compliance with safety standards. Consult a qualified technician if any issues arise during pre-installation checks.

Connecting to HomeFill System

To connect the Invacare concentrator to the HomeFill system, locate the designated outlet fitting on the concentrator. Attach the HomeFill compressor hose securely, ensuring no leaks. Follow the HomeFill user manual for connection procedures. Power on both devices and allow the system to pressurize. Monitor the oxygen concentration levels to ensure compatibility and proper function. The HomeFill system does not affect the concentrator’s performance. Always refer to the HomeFill manual for specific operating instructions and safety guidelines during the connection process.

Operation and Usage

The Invacare concentrator operates by separating oxygen from room air using molecular sieve technology to provide supplemental oxygen for patients with respiratory needs, delivering concentrations between 87% and 95.6% via a nasal cannula.

Starting the Concentrator

To start the Invacare concentrator, ensure it is placed on a stable surface and plugged into a grounded electrical outlet. Turn the power switch to the “ON” position. Allow the device to warm up for a few minutes until it reaches normal operation. Check for any alarm signals, which indicate issues like low oxygen levels or high temperature. Ensure the oxygen concentration level, ranging from 87% to 95.6%, is suitable for the patient’s needs. Always refer to the manual for specific startup procedures and safety guidelines.

Adjusting Flow Rate

Adjust the flow rate on your Invacare concentrator by turning the flowmeter knob to the desired setting, typically between 1 to 5 liters per minute. For flow rates below 1 liter, use the Invacare Pediatric Flowmeter accessory. Always refer to the user manual for specific instructions. Ensure the oxygen is delivered through a nasal cannula, and verify the flow rate matches the prescription. Proper adjustment ensures optimal oxygen therapy and patient comfort. Consult a healthcare professional if unsure about the correct flow rate for specific medical conditions.

Maintenance and Care

Regular maintenance ensures optimal performance. Clean the exterior with a damp cloth and check filters monthly. Schedule professional servicing annually to maintain compliance and functionality.

Routine Maintenance Tasks

Regular maintenance is crucial for optimal performance. Clean the exterior with a damp cloth and avoid harsh chemicals. Inspect and replace filters every 1-2 months or as indicated. Check for dust buildup in vents and ensure proper airflow. Schedule annual professional servicing to maintain compliance and functionality. Refer to the manual for specific tasks and intervals. Always follow safety guidelines to ensure the concentrator operates safely and effectively for patient care.

Troubleshooting Common Issues

Identify and resolve common issues promptly to ensure uninterrupted operation. Low oxygen levels may indicate a dirty or worn filter, requiring replacement. Alarm sounds signal issues like high temperature or low airflow, often due to blocked vents. Power issues may result from faulty outlets or tripped circuit breakers. Consult the manual for specific error codes and solutions. Regularly cleaning filters and ensuring proper ventilation can prevent many problems. Always follow safety guidelines when troubleshooting to maintain patient safety and device efficiency.

Safety and Precautions

Always read the manual thoroughly before use. Understand safety symbols and follow guidelines to avoid hazards. The device is not intended for life support.

Understanding Alarm Systems

The Invacare concentrator features an advanced alarm system to alert users of potential issues. Alarms may sound for low oxygen levels, high temperature, or power failures. Refer to the manual for specific alarm codes and troubleshooting steps. Understanding these signals ensures timely resolution of problems, maintaining patient safety and device efficiency. Regular checks and maintenance can prevent alarms from triggering unnecessarily, ensuring reliable operation.

Important Safety Guidelines

The Invacare concentrator must be used in well-ventilated areas, away from flammable materials. Never modify the device or use unauthorized parts. Ensure proper power supply and avoid overheating. Regularly inspect hoses and connections for damage. Always follow the manual’s instructions for operation and maintenance. Keep the concentrator out of reach of children. Failure to adhere to these guidelines may result in malfunction or safety hazards. Proper usage ensures safe and effective oxygen delivery for patients with respiratory needs.

Compatibility with HomeFill

The Invacare concentrator is designed to work seamlessly with the HomeFill system, enabling safe and efficient filling of oxygen cylinders for portable use, ensuring patient mobility and convenience.

Filling Oxygen Cylinders

The Invacare concentrator, when connected to the HomeFill system, allows for safe and efficient filling of oxygen cylinders. Ensure the outlet fitting is correctly attached to avoid affecting concentrator performance. Always refer to the HomeFill user manual for specific connection and operating instructions. Properly monitor pressure levels during the filling process to maintain safety standards. This feature enhances patient mobility by providing a reliable source of oxygen for portable use. Always follow the recommended safety protocols and guidelines outlined in both the Invacare and HomeFill manuals for optimal results.

Compatible Models and Accessories

The Invacare concentrator is compatible with specific models such as IRC5LXAW and IRC5LXO2AW, ensuring seamless integration with the HomeFill system. Accessories like the SensO2 oxygen sensor and pediatric flowmeter enhance functionality. The Platinum Series models, including the IRC5PO2V, are designed to work with the HomeFill compressor for cylinder filling. Always use Invacare-approved accessories to maintain performance and safety. Refer to the manual for a full list of compatible models and recommended accessories to ensure optimal operation and compliance with safety standards.

Regulatory and Service Information

Invacare concentrators comply with FDA and CE standards, ensuring safety and efficacy. Regular servicing by certified technicians is required to maintain warranty and optimal performance.

Compliance and Certification

Invacare concentrators are designed to meet rigorous regulatory standards, ensuring safety and efficacy. They comply with FDA and CE requirements, adhering to international quality norms. The devices are certified to ISO standards, guaranteeing reliable performance. Compliance with these regulations ensures the concentrators deliver consistent oxygen therapy, meeting patient needs effectively. Regular maintenance by certified technicians is essential to uphold certification standards and ensure ongoing compliance with safety guidelines.

Service Intervals and Technician Requirements

Regular servicing is crucial for maintaining the Invacare concentrator’s performance. Factory-trained technicians should perform annual maintenance, including filter replacements and system checks. Additional services may be needed based on usage and environmental conditions. Only authorized personnel with proper qualifications should conduct repairs to ensure compliance with safety standards and warranty terms. Adhering to recommended service intervals prevents operational issues and extends the device’s lifespan, ensuring reliable oxygen delivery for patients.

Resources and Support

Invacare provides comprehensive support resources, including downloadable user manuals, service guides, and contact information for technical assistance, ensuring optimal product understanding and troubleshooting.

Accessing User Manuals

Invacare provides easy access to user manuals for their oxygen concentrators. Visit www.invacare.com to download PDF versions of manuals for models like the Perfecto2 Series. These manuals include detailed instructions for operation, maintenance, and troubleshooting. Additionally, manuals are often included in the product packaging or available through authorized distributors. For specific models, such as the Perfecto2 IRC5PO2AW, refer to part numbers like 1145804 for Northern regions. Manuals also cover preventive maintenance tasks, ensuring optimal device performance and safety.

Contact Information for Assistance

For questions or issues regarding your Invacare oxygen concentrator, visit the official Invacare website at www.invacare.com for comprehensive support. Contact authorized Invacare dealers or distributors for technical assistance. Customer service and technical support teams are available to address inquiries and provide troubleshooting guidance. Ensure to reach out to certified professionals for maintenance and repairs to maintain warranty validity and device performance.

Leave a Reply